Oxygen gas plant , Nitrogen gas plant , Acetylene gas plant Trouble Shooting


Hopper selected by selector switch position does not run:
Generator high pressure switch set too low. Check and reset the pressure switch.
Power off long enough for pressure to drop so that other hopper will start when power comes on.
Trouble will cease when power outage cheeses.
Overload tripped on one hopper Reset power starter overload really.
Generator pressure drops below generator low pressure switch setting and pressure does not built up again:
Screw feed does not run. Repeat 10.1.11.
Safety valve vent lever open . Move it to proper position.
Check hopper pressure. Is hopper pressure more than the tank pressure? If so check pressure on flash back arrestor
Hopper hydraulic valve not opening. If flash back arrestor pressure is okay see 10.5.1.2 it it is not see, 10.5.1.1
Check oil pre=5ure. If it is belO1-J /5 Psig, check the opening of the bypass valve and alsc the oil level. Fortify the abnormalities.
Screw feed does not run:
hopper starter overload. trippers.

Reset hopper starter overload.
Water level in generator too low. Check low level air pressure gauge. if it is above 7 Psig, it is okay.
Air supply pressure too low. Correct air supply pressure. Check to determine why alarm bell was not ringing and rectify the same.
generator pressure above 17 Psig generator safety valve should be venting:
Water not added to compensate temp drop due to shut down. Water inlet pressure is not adequate or water meter is faculty, check.
Pointer on the temperature transmitter on extreme left:
Offset adjustment not properly set. Adjust nut.
Capillary tube is leaking. Replace capillary tube.
Cooler condenser:
Temperature of acetylene leaving cooler condenser above room temperature:
Water flow through cooler condenser not sufficient. Increase flow of water
Air trapped of cooler condenser Open air vent valve to trapped air.

5






Universal Industrial Plants Mfg. Co. (P) Ltd.
A 104/2, Okhla Industrial Area, Phase-2, New Delhi – 110 020
Phone :+(91)-(124)-4386250, +(91)-(124)-5519863 Fax :+(91)-(124)-4386234
Mobile : +(91)-9810626301
Email : info@oxygengasplant.net , info@universalboschi.com

   
   

This design is a copyright of Ing L&A BOSCHI Italy and Universal Industrial Plants Mfg. Co. and copy of any written material, photographs and diagrams from website is strictly prohibited. Any unauthorised use shall be liable for prosecution