Trouble Shooting Mechanism for oxygen plant, Nitrogen Plant , Acetylene Plant


Alarm bell rings and temperature alarm transmitter air pressure gauge is below 7 Psig:
Surface temperature of the tank approximately same allover or temperature above water line is cooler than below water line.
Water supply pressure low . Check the water pump.
Water line valve not open. Open valve
Temperature alarm transmitter set point is less than water inlet control temp transmitter set point. Set temperature alarm 10 deg C above water inlet transmitter.
Water to carbide rati0 below 10.0 liters/kg of Carbide. Set the water inlet temperature transmitter at a lower level as discussed in 7.3.2 .

Tank above water level becomes warier than tank below water level and tank pressure abscise 10 psig:
Water not added to compensate for temp drop due to shut down .

Turn off hopper toggle switch. stop acetylene compressor when acetylene pressure goes below 5psig Bimanually operating the safety relief valve reduce to generator press we to 7 psig and add about 1000 liters of water by moving the water control temperature transmitter.
Restart the generator when the ,conditions are normal.
Top portion of acetylene generator tank above water level becomes warmer than that of bottom and tank pressure normal at 5 psig.
Incorrect carbide to water ratio.
Turn off hopper toggle switch and stop acetylene compressor when pressure drops to 5 psig Add about 1'000 liters of 'water by adjusting the set point of the. water inlet control temperature transmitter.
Water not added to compensate for drop in temp due to shut down. Add water turn on hopper toggle switch when conditions are normal.
Temperature at bottom of acetylene generator tank is not as same as position of tank just below water level.
Insufficient agitation of sludge. Check to see the shaft on opposite and from drive when the agitator drive runs.
Agitators drive shaft turning on drive end but not on opposite end .
Broken shaft or sheared bolts. stop the screw feeder vent off acetylene gas, flush thoroughly replace the shaft.

Alarm bell rings all air pressure gauges are below 7 psig:

Correct are pressure is not being maintained.

Check to see that air compressor is running . Check to serif air compressor tank drain valve is closed .

Generator alarm light not on:
Light burnt out. Replace lamp.
Alarm switched off. Turn on switch.
Alarm fuse burnt out. Replace fuse.
Power fse to generator motor starters burnt out. Check and replace burnt out fuse.
Hopper pressure can not be vented for Hooper filling:
Carbide lodged between feed valve and seat.
Move selector switch to run empty hopper. Return selector switch to run full hopper. Repeat the same till it is normal.
Open end of the screw when the generator was cleaned. Turn off hopper toggle tank. Remove top plate from end of screw feeder and clean the open end.

5





UNIVERSAL PLANTS MANUFACTURING INDIA PVT LTD
Okhla Industrial Area, New Delhi, India.
Phone :+(91)-(124)-4386250, +(91)-(124)-5519863 Fax :+(91)-(124)-4386234
Mobile : +(91)-9810626301
Email : info@oxygengasplant.net , info@universalboschi.com

   
   

This design is a copyright of Ing L&A BOSCHI Italy and Universal Industrial Plants Mfg. Co. and copy of any written material, photographs and diagrams from website is strictly prohibited. Any unauthorised use shall be liable for prosecution